Friday 18 May 2012

PHILIPS TRANSDUCERS

S5-1

Sector Array Transducer with PureWave Crystal Technology

 
  • 5 to 1 MHz extended operating frequency range
  • PureWave crystal technology - increases bandwidth and efficiency for broader patient range and improved clinical performance
  • 2D, steerable PW Doppler and CW Doppler, High PRF Doppler, Color Doppler, Tissue Doppler, XRES, and Harmonic Imaging including LVO
  • Adult, pediatric, and congenital heart disease applications

Systems that use this transducer:


S8-3

Broadband Sector Array Transducer

 
  • 8 to 3 MHz extended frequency range
  • Field of view: 90°
  • 2D, steerable PW Doppler and CW Doppler, High PRF Doppler, Color Doppler, Tissue Doppler, XRES, and Harmonic Imaging
  • Adult and pediatric cardiology applications, fetal echo

Systems that use this transducer:















S12-4

Sector Array Transducer

 
  • 12 to 4 MHz extended frequency range
  • Field of view: 90°
  • 2D, steerable PW Doppler and CW Doppler, High PRF Doppler, Color Doppler, Tissue Doppler, XRES, and Harmonic Imaging
  • Cardiac intraoperative, Tissue Doppler, and epicardial imaging
  • Pediatric and adult cardiology applications

Systems that use this transducer:

 


X3-1

Broadband xMATRIX Array Transducer

 
  • 3 to 1 MHz extended operating frequency range
  • 2D xMATRIX phased array with 2,400 elements
  • 2D, biplane (Live xPlane), triggered full volume, Live 3D Echo, Color Doppler with 2D, biplane and 3D, XRES, Harmonic Imaging, LVO
  • Adult and pediatric cardiology applications
  • Epicardial imaging
  • Supports reusable plastic biopsy guide (dual angle) (14-23 gauge)
  • Explora connector with exceptional broadband response and new cable technology that is extremely flexible and lightweight

Systems that use this transducer:



X7-2

xMATRIX Array Transducer

 The new X7-2 transducer combines xMATRIX technology with PureWave crystal technology for remarkable imaging in small pediatric patients.

  • 2D matrix array with 2,500 elements
  • 7 to 2 MHz extended operating frequency range
  • 2D, biplane (Live xPlane), triggered full volume, Live 3D Echo (iE33) or Live Volume imaging (iU22), color Doppler and PW Doppler with 2D, biplane and 3D, XRES, and Harmonic Imaging
  • Neonatal and pediatric cardiology applications (iE33)
  • Epicardial imaging (iE33)
  • Pediatric abdomen, neonatal head, and fetal echo (iU22)

Systems that use this transducer:


X7-2t TEE

2D and Live 3D TEE xMATRIX Array

 iE33 Live 3D TEE TransducerOn the iE33 xMATRIX system, the X7-2t transducer combines xMATRIX array and PureWave crystal technologies in a fully functional TEE probe for remarkable Live 3D Echo performance during transesophageal exams.
  • 2D and 3D matrix array
  • 7 to 2 MHz extended operating frequency range
  • 2D, color flow, PW Doppler, CW Doppler, M-mode, Live xPlane imaging, Live 3D Echo, Live 3D zoom, advanced XRES, triggered full volume, triggered 3D color
  • Harmonic imaging
  • Dynamic elevational focusing
  • Electrocautery suppression
  • Electronic rotatable array from 0 to 180 degrees
  • TEE applications for patients >30 kg/66 lb

CX50 and Sparq TEE Transducer
On the CX50 and Sparq systems, the X7-2t transducer combines xMATRIX and PureWave crystal technologies in a TEE probe for remarkable image quality in 2D transesophageal exams.
  • 2D matrix array
  • 7 to 2 MHz extended operating frequency range
  • 2D, color flow, PW Doppler, CW Doppler, M-mode, advanced XRES
  • Harmonic imaging
  • Dynamic elevational focusing
  • Electrocautery suppression
  • Electronic rotatable array from 0 to 180 degrees
  • TEE applications for patients >30 kg/66 lb

An optional transducer adapter is available for purchase that enables the
CX50 and Sparq X7-2t transducer to be used in both 2D and 3D modes on an iE33 system.

Systems that use this transducer:

 


S7-2t

Omni Sector Array

 
  • Transesophageal phased array
  • 7 to 2 MHz extended operating frequency range
  • 180 degrees electronic rotation
  • Field of view: 90°
  • Electrocautery suppression
  • 2D, Steerable PW Doppler, CW Doppler, High PRF Doppler, Color Doppler, Tissue Doppler, XRES, Harmonic Imaging, LVO
  • Adult TEE applications

Systems that use this transducer:





C6-2

Broadband Curved Array Transducer

  • 6 to 2 MHz extended frequency range
  • Field of view: 70 degrees
  • 2D, steerable PW Doppler, High PRF Doppler, Color Doppler, Color Power Angio, SonoCT, advanced XRES, and multi-variate Harmonic Imaging
  • General purpose abdominal, pelvic (includes obstetrical and gynecological), trauma, and regional anesthesia applications
  • Supports 4 angle disposable Ultra-Pro II gauges 8.5, 14-25 GA (19 GA not available)

Systems that use this transducer:


L12-4

Broadband Sector Linear Array Transducer

  • 12 to 4 MHz extended frequency range
  • 2D, steerable PW Doppler, High PRF Doppler, Color Doppler, Color Power Angio, M-mode, SonoCT, advanced XRES, and multi-variate Harmonic Imaging
  • Regional anesthesia, vascular, superficial, musculoskeletal, lung, and trauma applications
  • Supports disposable infinite angle and a disposable AccuSite guide

Systems that use this transducer:

 

S4-2

Broadband Sector Array Transducer

/iw-mount/default/main/publicweb_healthcare/global/main/shared/STAGING/Assets/Images/Ultrasound/Product/Transducers/S4-2.jpg 
  • 4 to 2 MHz extended frequency range
  • 2D, steerable PW Doppler, CW Doppler, High PRF Doppler,
    Color Doppler, Color Power Angio, Tissue Doppler,
    M-mode, advanced XRES, and multi-variate Harmonic Imaging
  • Adult cardiac, general purpose abdominal and trauma
  • Supports reusable 3-angle plastic biopsy guide and 3-angle stainless steel biopsy guide

Systems that use this transducer:

 

C9-4v

Broadband Curved Array Transducer

  • 9 to 4 MHz extended frequency range
  • Field of view: 150 degrees
  • 2D, steerable PW Doppler, High PRF Doppler, Color Doppler, Color Power Angio, SonoCT, advanced XRES, and multi-variate Harmonic Imaging
  • Endovaginal applications
  • Supports disposable biopsy guide, reusable stainless steel biopsy guide and disposable quick release biopsy guide

Systems that use this transducer:


C5-2

Broadband Curved Array Transducer

C5-2 Broadband Curved Array 
  • 5 to 2 MHz extended operating frequency range
  • Field of view: 75°
  • 2D, steerable pulsed wave and color Doppler, High-PRF Doppler, Color Power Angio, SonoCT, XRES, Panoramic, Freehand 3D and harmonic imaging*
  • Abdominal, cardiac, and Ob/Gyn applications
  • Contrast applications
  • Supports biopsy guide capabilities




Systems that use this transducer:

iE33iU22HD15HD11 XE

HD9HD7




C8-5

Broadband Curved Array Transducer

C8-5 Broadband Curved Array 
  • 8 to 5 MHz extended operating frequency range
  • 2D, steerable pulsed wave and color Doppler, M-mode, Color Power Angio, SonoCT, Freehand 3D, Panoramic, and XRES imaging*
  • Ob/Gyn, fetal echo, vascular, pediatric, neonatal, and urology applications
  • Supports biopsy guide capabilities.



Systems that use this transducer:





L8-4

Broadband Linear Array Transducer

 
  • 8 to 4 MHz extended operating frequency range
  • Steerable pulsed Doppler, Color Doppler, and Color Power Angio, SonoCT, XRES, Panoramic, and Harmonic Imaging
  • Vascular (carotid, arterial and venous) and internal mammary vessel applications
  • General imaging, vascular, and superficial imaging applications
  • Supports biopsy guide capabilities

Systems that use this transducer:

 

S7-3t TEE

Pediatric TEE Broadband Sector Array Transducer

 
  • 7 to 3 MHz extended operating frequency range
  • Transesophageal phased array
  • Field of view: 90°
  • 180 degrees mechanical rotation
  • 2D, steerable pulsed wave Doppler, CW Doppler, color Doppler, XRES, and harmonic imaging
  • Pediatric and small adult TEE applications

Systems that use this transducer:




L11-3

Broadband Linear Array Transducer

 
  • 11 to 3 MHz extended operating frequency range
  • Steerable pulsed Doppler, color Doppler, and Color Power Angio, SonoCT, XRES, and Harmonic Imaging
  • Vascular (carotid, arteria and venous) and superficial imaging applications
  • Cerebrovascular (carotids, vertebrals), peripheral vascular (venous, arterial), and internal mammary vessels

Systems that use this transducer:


X3-1

Broadband xMATRIX Array Transducer

 
  • 3 to 1 MHz extended operating frequency range
  • 2D xMATRIX phased array with 2,400 elements
  • 2D, biplane (Live xPlane), triggered full volume, Live 3D Echo, Color Doppler with 2D, biplane and 3D, XRES, Harmonic Imaging, LVO
  • Adult and pediatric cardiology applications
  • Epicardial imaging
  • Supports reusable plastic biopsy guide (dual angle) (14-23 gauge)
  • Explora connector with exceptional broadband response and new cable technology that is extremely flexible and lightweight

Systems that use this transducer:


L9-3

Broadband Linear Array Transducer

 
  • 9 to 3 MHz extended operating frequency range
  • 15 degrees of trapezoid imaging
  • 38 mm effective aperture length
  • Steerable pulsed Doppler, Color Doppler, and Color Power Angio, SonoCT, XRES, Panoramic, and Harmonic Imaging
  • Vascular (carotid, arterial and venous) and superficial imaging applications
  • Cerebrovascular (carotids, vertebrals), peripheral vascular (venous, arterial), and internal mammary vessels
  • Contrast applications
  • Precision Doppler with Fine Angle Steering
  • Supports biopsy guide capabilities 



Systems that use this transducer:



HD9

X5-1

xMATRIX array with PureWave technology

X5-1 The new X5-1 transducer helps remove the barriers to 3D imaging, giving clinicians the power to choose 2D, 3D or combination imaging without disrupting workflow. Combining xMATRIX array technology with PureWave crystal technology for consistently excellent image quality, the X5-1 supports 3D, 2D, color flow, M-mode, PW/CW Doppler, Tissue Doppler imaging, and contrast-enhanced exams.
  • 3,040 elements with microbeamforming
  • 1 to 5 MHz extended operating frequency range
  • 2D, Live 3D volume, high volume rate (HVR), one-beat, two-beat and four-beat Live volume, color flow, Live 3D color, PW/CW Doppler, M-mode, color M-mode, contrast, Tissue Doppler imaging, Live xPlane imaging
  • iRotate – Electronically rotatable scan angle from 0 to 180 degrees 
  • Adult, contrast LVO, pediatric CHD, cardiology coronary
  • New ergonomic design for reduced user fatigue
  • Solid state reliability and no complex liquid cooling required
  • Philips green label approved transducer
  • Dimensions: 9.2 x 3.9 x 2.9 cm (3.6 x1.5 x 1.1 in) LWD

Systems that use this transducer:



L15-7io

Broadband Compact Linear Array Transducer

 
  • 15 to 7 MHz extended frequency range
  • 23 mm effective aperture length
  • 8° of trapezoidal imaging; 23 mm effective aperture length
  • Steerable pulsed Doppler, Color Doppler, and Color Power Angio, XRES, and Panoramic imaging
  • High-resolution intraoperative vascular applications
  • Superficial small parts and musculoskeletal imaging



Systems that use this transducer:

 

D2cwc

Continuous Wave Transducer (Pedoff)

 
  • Dedicated 2 MHz continuous wave Doppler
  • Adult cardiology applications

Systems that use this transducer:



HD9

D5cwc

Continuous Wave Transducer (Pedoff)

 
  • Dedicated 5 MHz continuous wave Doppler
  • Deep venous and arterial applications

Systems that use this transducer:





S8-3t

Sector array multiplane microTEE

 
  • Micro transesophageal sector array
  • 8 to 3 MHz extended operating frequency range
  • Physical dimensions
    • Tip: 7.5 x 5.5 x 18.5 mm (width, height, length)
    • Shaft diameter: 5.2 mm
    • Adult length gastroscope: 85 cm

  • Manually rotatable multiplane array from 0 to 180 degrees
  • Manual control of anterior and posterior flexion
  • 2D, steerable PW Doppler, CW Doppler, color Doppler, advanced XRES, M-mode, and harmonic imaging
  • Pediatric, including infants, and adult TEE application

Systems that use this transducer:


D2tcd

Pulsed Wave Transducer (Pedoff)

 
  • Dedicated 2 MHz pulsed wave Doppler
  • Transcranial Doppler applications
  • Peripheral vascular applications

Systems that use this transducer:

C5-1

Broadband Curved Array Transducer with PureWave Crystal Technology

 
  • 5 to 1 MHz extended operating frequency range
  • Steerable pulsed, High-PRF and color Doppler; and Color Power
  • Angio, SonoCT, advanced XRES, and multi-variate harmonic imaging
  • General purpose abdominal, obstetrical,  gynecological, and interventional applications
  • Discreet TSI for deep abdominal, obstetrical, and gynecological penetration enables:
    • Tissue aberration correction
    • Coded beamforming with chirp transmit and coded harmonics
  • Supports biopsy guide capabilities

* Not all features available on all systems

Systems that use this transducer:

 

TY-306

Heartsound Pulse Contact Sensor

  • Patient heartsound and carotid pulse
  • 0.04 to 300 Hz frequency response
  • For cardiac and vascular applications

Systems that use this transducer:



C10-3V

C10-3v broadband curved array with PureWave crystal technology
 
  • 10 to 3 MHz extended operating frequency range
  • End-fire sector, 11.5 mm radius of curvature, 130° field of view
  • Steerable pulsed wave and color Doppler, Color Power Angio, advanced XRES, and harmonic imaging
  • Endovaginal applications
  • Supports biopsy guide capabilities

Systems that use this transducer:


C9-5ec

Broadband Curved Array Transducer
 
  • 9 to 5 MHz extended frequency range
  • End-fire sector, 8 mm radius of curvature, 150ยบ field of view
  • Steerable pulsed wave and color Doppler, Color Power Angio, Freehand 3D, Panoramic, SonoCT, XRES, and harmonic imaging*
  • Endocavitary applications including vaginal and rectal
  • Contrast applications
  • Supports biopsy guide capabilities

* All features not available on all systems

Systems that use this transducer:



C8-4v

Broadband Curved Array Transducer

C8-4v Broadband Curved Array 
  • 8 to 4 MHz extended operating frequency range
  • End-fire sector, 11 mm radius of curvature
  • 2D, steerable pulsed wave and color Doppler, M-mode, Color Power Angio, SonoCT, XRES, Panoramic, Freehand 3D and harmonic imaging*
  • Endovaginal applications
  • Contrast applications
  • Supports biopsy guide capabilities

*Not all features are available on all systems.


Systems that use this transducer:

HD9

HD7 XEHD 6

VL13-5

Broadband Linear Array
 
  • 13 to 5 MHz extended operating frequency range
  • Fine pitch, 192 element, high resolution linear array
  • Steerable pulsed wave and color Doppler, Color Power Angio, SonoCT, XRES, and harmonic imaging
  • Supports high resolution 2D imaging
  • Supports high resolution, quantitative, single sweep 3D volume acquisition 
  • Supports 4D imaging
  • High resolution superficial applications including small parts, breast, and vascular imaging
  • Tissue aberration correction selection for advanced breast imaging TSI
  • Supports biopsy guide capabilities

Systems that use this transducer:


3D9-3v

Broadband Curved Array Transducer

 
  • 9 to 3 MHz extended frequency range
  • 130° field-of-view
  • Supports high resolution 2D imaging
  • Supports high resolution, quantitative, single sweep 3D volume acquisition (hybrid and freehand).
  • Supports 4D imaging up to 22 volumes per second
  • Steerable pulsed wave and color Doppler, Color Power Angio, SonoCT, XRES, Panoramic, and harmonic imaging
  • Endovaginal applications
  • Supports biopsy guide capabilities

Systems that use this transducer:

iU22HD11 XEHD 15

L17-5

Broadband Linear Array Transducer
 
  • 17 to 5 MHz extended frequency range
  • Ultra-fine pitch, high resolution linear array
  • 38 mm effective aperture length
  • Steerable pulsed wave and color Doppler, Color Power Angio, SonoCT, XRES, and harmonic imaging
  • Tissue aberration correction selection for advanced breast imaging TSI
  • High-resolution superficial applications including small parts, breast, superficial vascular, and musculoskeletal imaging
  • Elastography 
  • Supports biopsy guide capabilities

Systems that use this transducer:


L12-5 50 mm

Broadband Linear Array Transducer

L12-5 50 mm Broadband Linear Array 
  • 12 to 5 MHz extended operating frequency range
  • Fine pitch, high resolution linear array
  • 50 mm effective aperture length
  • 10 degrees of trapezoidal imaging
  • Steerable pulsed wave, color Doppler, and Color Power Angio, Panoramic, SonoCT, XRES, and harmonic imaging*
  • High resolution superficial applications including vascular, small parts, breast, and musculoskeletal imaging
  • Contrast applications*
  • Elastography (iU22 system only)
  • Supports biopsy guide capabilities

* Not all features are available on all systems

Systems that use this transducer:

iU22HD15HD11 XEHD9

HD7 XE


S4-1

Broadband Sector Array Transducer
 
  • 4 to 1 MHz extended frequency range
  • Steerable pulsed wave Doppler, High-PRF Doppler, color Doppler, Color Power Angio, XRES, and harmonic imaging
  • Deep abdominal, obstetrical, gynecological, and interventional applications
  • Supports biopsy guide capabilities
  • Contrast applications

Systems that use this transducer:


S3-1

Broadband Sector Array Transducer
 
  • 3 to 1 MHz extended frequency range
  • Steerable CW Doppler, PW Doppler, High PRF Doppler, Color Doppler, Color Power Angio, Tissue Doppler Imaging, Freehand 3D, XRES, and Harmonic Imaging
  • 90° field-of-view
  • Contrast applications
  • Adult cardiology applications, and transcranial Doppler
  • Explora connector with exceptional broadband response and new cable technology that is extremely flexible and lightweight

Systems that use this transducer:

 

X6-1

xMATRIX Array Transducer with PureWave Crystal Technology
 
  • 6 to 1 MHz extended operating frequency range
  • Fully-sampled matrix phased array with 9,212 elements
  • Dynamic focusing over range in both lateral and elevation dimensions
  • Three line densities in 3D and 4D modes
  • General purpose abdominal, obstetrical, fetal echo, and gynecological applications
  • 2D modes include 2D, M-mode, color Doppler, Color Power Angio including directional CPA, pulsed Doppler, elevation compounding, biplane (Live xPlane) with color, 3D with color and CPA, 4D, triggered full volume with color, advanced XRES, and harmonic imaging
  • Auto-heart detection for triggered full volume fetal echo in grayscale and color
  • Supports biopsy guide capabilities

Systems that use this transducer:


C6-3

Broadband Curved Array Transducer
C6-3 Curved Array 
  • 6 to 3 MHz extended operating frequency range
  • 50 mm radius of curvature
  • 2D, steerable pulsed Doppler, color Doppler, M-mode, Color Power Angio, SonoCT, harmonic imaging, Panoramic, XRES, and Freehand 3D
  • Abdominal, Ob/Gyn, pediatric, urology, emergency medicine, and regional anesthesia applications
  • Narrow footprint for improved intercostal access
  • Multi-angle biopsy kit available

Systems that use this transducer:

HD9

L12-3

Broadband Linear Array Transducer

L12-3 Broadband Linear Array 
  • 12 to 3 MHz extended frequency range
  • 35 mm effective aperture length
  • 10° of trapezoidal imaging
  • Steerable pulsed wave and color Doppler and Color Power Angio, SonoCT, XRES, Panoramic and harmonic imaging
  • High-resolution superficial applications including small parts, breast, superficial vascular, and musculoskeletal imaging
  • Supports biopsy guide capabilities

Systems that use this transducer:



HD6


C9-3v

Curved array with PureWave crystal technology
 
  • 9 to 3 MHz extended operating frequency range
  • High density curved array, 128 elements
  • End-fire sector, 11.5 mm radius of curvature, 130° field-of-view
  • Steerable pulsed wave, High PRF, and color Doppler, Color Power Angio, SonoCT, advanced XRES, and multi-variate harmonic imaging
  • Endovaginal applications
  • Supports disposable plastic biopsy guide (18 gauge) and stainless steel biopsy guide (16-18 gauge)


Systems that use this transducer:

 

L12-3

Broadband Linear Array Transducer

L12-3 Broadband Linear Array 
  • 12 to 3 MHz extended frequency range
  • 35 mm effective aperture length
  • 10° of trapezoidal imaging
  • Steerable pulsed wave and color Doppler and Color Power Angio, SonoCT, XRES, Panoramic and harmonic imaging
  • High-resolution superficial applications including small parts, breast, superficial vascular, and musculoskeletal imaging
  • Supports biopsy guide capabilities

Systems that use this transducer:



HD6

S5-2

Broadband Sector Array Transducer with PureWave Crystal Technology
 
  • 5 to 1 MHz extended operating frequency range
  • Phased array with 80 elements
  • Field of view: 90°
  • 2D, steerable PW Doppler and CW Doppler, High-PRF Doppler, color Doppler, Tissue Doppler, XRES, Freehand 3D, and harmonic imaging including LVO
  • Cardiac, abdominal, TCD and obstetrics, fetal echo, and emergency medicine applications

Systems that use this transducer:


BP10-5ec

Broadband Biplane Curved Array Transducer

 
  • 10 to 5 MHz extended frequency range
  • Field of view: 126°
  • Biplane intersecting sagittal and transverse sectors, 8 mm radius of curvature
  • Steerable pulsed wave and color Doppler, Color Power Angio, harmonic, Freehand 3D, Panoramic, SonoCT, and XRES imaging
  • Endorectal and endovaginal applications for urology
  • Biopsy kit available

Systems that use this transducer:


Volume Curved Array
 
  • 8 to 4 MHz extended operating frequency range
  • Field of view: 85 degrees
  • Steerable pulsed Doppler, High-PRF Doppler, color Doppler, Color Power Angio, SonoCT, XRES, Panoramic, harmonic, and STIC imaging
  • Supports high resolution 2D imaging
  • Supports high resolution, quantitative, single sweep 3D volume acquisition 
  • Supports 4D imaging up to 30 volumes per second
  • Supports 3D color Doppler
  • General purpose small adult and pediatric abdominal, obstetrical, and gynecological applications
  • Supports biopsy guide capabilities

Systems that use this transducer:


3D8-4

Broadband Curved Array Transducer

 
  • 8 to 4 MHz extended frequency range
  • 68° field-of-view
  • Supports: high resolution 2D imaging
  • Supports high resolution, quantitative, single-sweep 3D volume aquisition 
  • Supports 4D imaging up to 30 volumes per second
  • Supports 3D fetal echo STIC
  • Supports 3D color Doppler
  • Steerable pulsed Doppler, high-PRF Doppler, color Doppler, and Color Power Angio, SonoCT, XRES, Panoramic and Harmonic Imaging
  • General purpose small adult and pediatric abdominal, obstetrical, and gynecological applications
  • Supports reusable plastic bracket with disposable biopsy guides (dual angle, 14-23 gauge)
  • Explora connector with new cable technology that is extremely flexible and lightweight

Systems that use this transducer:


V9-4v

Volume Curved Array Transducer

 
  • 9 to 4 MHz extended operating frequency range
  • 150° field of view
  • 2D, 3D, and 4D imaging including color Doppler, STIC, PW Doppler, M-mode and CPA
  • Biopsy kit available


Systems that use this transducer:


V7-3

Volume Curved Array

 
  • 7 to 3 MHz extended operating frequency range
  • 84° field of view
  • Supports 2D, 3D, and 4D imaging including Color Flow, PW Doppler, M-mode and CPA
  • Biopsy kit available


Systems that use this transducer:


S12

Sector Array
s12 Sector Array 
  • 12 to 5 MHz extended operating frequency range
  • Provides high-resolution imaging for pediatric echo and neonatal cephalic applications
  • Supports 2D, color, PW/CW Doppler, and Color Power Angio imaging

Systems that use this transducer:


S8

Sector Array Transducer
s8 Sector Array 
  • 8 to 3 MHz extended operating frequency range
  • High-resolution imaging for pediatric and ob/gyn applications
  • Supports 2D, color, PW/CW Doppler, and Color Power Angio imaging

Systems that use this transducer:

 

15-6L

Compact Linear Array
15-6L Compact Linear Array 
  • 15 to 6 MHz extended operating frequency range
  • Phased linear array with 128 elements
  • 8° of trapezoidal imaging
  • Provides high-resolution imaging for epicardial, intraoperative, and vascular applications
  • Supports 2D, color, PW Doppler, and Color Power Angio imaging

Systems that use this transducer:


Omni III

OmniPlane III TEE

Omni III TEE The new OmniPlane III TEE transducer further advances Philips’ proven OmniPlane technology. Omni III’s Ultraband 2- to 7-MHz frequency range provides the necessary bandwidth for harmonic imaging and contrast research applications.

  • Harmonic imaging reduces artifacts and improves images in difficult-to-image patients, providing superb endocardial definition for the evaluation of wall motion.
  • True electrocautery suppression provides virtual elimination of unavoidable noise artifact in 2D/harmonics and significant reduction of artifact in color flow.
  • Adaptive AutoCool automatically changes any imaging mode to fundamental 2D imaging when the probe tip reaches 42°C, preventing imaging downtime and enabling the user to concentrate on patient care rather than the system.
  • Advanced contrast imaging tools, including LVO and MCE, are finally available on a TEE transducer for research.
  • The balanced, ergonomically designed control handle makes OmniPlane III easy to hold and operate.

Note: SONOS 5500 customers will need the Ultraperformance upgrade to use the OmniPlane III TEE transducer.

Systems that use this transducer:


D5009v

Cardiac/vascular non-imaging transducer
D5009v cardiac/vascular non-imaging 
  • 5 MHz, 9 mm diameter pencil transducer
  • Non-imaging PW/CW Doppler for cardiac and vascular applications

Systems that use this transducer:

HD7 XE

D1914C

Cardiac Non-imaging Transducer

D1914C cardiac Non-imaging 
  • 1.9 MHz pencil transducer
  • Non-imaging CW Doppler for cardiac applications

Systems that use this transducer:

HD7HD7 XE

S6-2mpt

Sector Array
S6-2mpt Sector Array 
  • 6 to 2 MHz extended frequency range
  • 180° mechanical rotation, 90° field-of-view
  • Supports 2D, Tissue Harmonic Imaging, color, PW/CW Doppler and Color Power Angio imaging
  • High-frequency transesopageal imaging with true electrocautery suppression and advanced ergonomics
  • Not available for sale in all geographies

Systems that use this transducer: